Outdoor lighting guide

Practical guidance for planning outdoor lighting: how high, how far apart, which optic and colour, and what the ratings on a datasheet mean.

Heights and spacing

Typical starting points by kind of space. On roads, poles usually stand three to four times their mounting height apart. Go wider and dark patches appear between them.
SpaceProductMounting heightSpacingColour temperature
Garden paths and walkwaysBollards0.6 – 1.0 m4 – 8 m2700 – 3000 K
Gardens and villa groundsGarden post tops2.5 – 3.5 m10 – 15 m2700 – 3000 K
Heritage streets and plazasCast iron and lantern poles3 – 5 m12 – 20 m2700 K
Society and internal roadsRound or square poles4 – 6 m15 – 25 m3000 K
Avenues and campus roadsArchitectural or square poles6 – 8 m20 – 30 m3000 – 4000 K
Main roadsArm-mounted street poles9 – 12 m30 – 40 m4000 K
Car parks and yardsArea lighting poles8 – 12 m25 – 35 m4000 K
Sports groundsArea masts12 – 15 mSet by layout4000 K

One side

Road narrower than the mounting height

Staggered

Road up to 1.5 times the mounting height

Opposite

Road wider than 1.5 times the mounting height

Central median

Divided roads, with twin-arm poles in the median

How many poles for a road?

600 m
7 m
Mounting height

Suggested arrangement

One side

Road narrower than the mounting height

Spacing
28 m
Poles
22
Luminaires
22

A first estimate for budgeting. Final spacing comes from a lighting calculation for the road class, luminaire and optics.

Light distribution

The optic decides the shape of the pool of light on the ground. Matching it to the space puts light where people walk and drive, and keeps it off windows and the sky.
  • Type I

    Narrow, two-way

    A long, narrow pool that runs along the path in both directions, with the pole in the middle of the walkway.

    Footpaths, cycle tracks, garden walks

  • Type II

    Wide, two-way

    Wider than Type I and set to one side, so a pole at the kerb lights the walkway and the edge of the road.

    Narrow roads, society lanes, promenades

  • Type III

    Forward throw

    Asymmetric light thrown forward across the road from a pole at its edge, with little spill behind.

    Roads, avenues, edges of car parks

  • Type IV

    Long forward throw

    A semicircle pushed far forward with almost nothing behind the pole. Good where the back of the pole faces a boundary or building.

    Perimeters, car parks, building frontages

  • Type V

    Symmetric, all round

    An even circle of light all round the pole. The natural choice for post tops, lanterns and 360° bollards in open space.

    Plazas, courtyards, junctions, parks

Plan views. Type names follow the IES classification used in photometric files. The dot marks the pole.

Colour temperature

Warmer light suits places people linger and anywhere near nature. Neutral white suits roads and car parks where contrast matters, and 6000 K cool daylight is kept for highways, yards and security lighting.
  • 2200 K

    Amber

    • Near wildlife, wetlands and coastline
    • Dark-sky and nature reserves
    • Insect-sensitive gardens
  • 2700 K

    Warm white

    • Heritage streets and conservation areas
    • Resorts, temples and hotel drives
    • Courtyards and dining terraces
  • 3000 K

    Soft white

    • Residential streets and societies
    • Gardens, parks and campus paths
    • Plazas and retail streets
  • 4000 K

    Neutral white

    • Main roads and highways
    • Car parks, yards and logistics
    • Sports grounds and security areas
  • 6000 K

    Cool daylight

    • Highways and expressways
    • Industrial yards and logistics hubs
    • Security and CCTV-monitored areas

IP and IK ratings

Two short codes say how well a fitting survives outdoors. IP covers dust and water, IK covers knocks and vandalism. They are tested separately, so check both.

IP65

The usual rating for outdoor luminaires on poles and bollards.

First digit: solids and dust

Dust tight: no dust enters

Second digit: water

Water jets from any direction

Impact resistance (IK)

Energy of the blow a fitting withstands without damage, tested to IEC 62262.

  • IK061 J0.25 kg from 400 mm
  • IK072 J0.5 kg from 400 mm
  • IK085 J1.7 kg from 300 mm
  • IK0910 J5 kg from 200 mm
  • IK1020 J5 kg from 400 mm

IK08 is a sensible minimum in public places. Bollards and low columns within reach of crowds are best at IK10.

Responsible lighting

Light that escapes upwards is wasted energy and hides the night sky. It also disturbs birds, insects and turtles on beaches. Five principles keep outdoor light where it belongs.
Unshielded globe: light lost to the sky
Full cut-off: all light goes down
  1. 01

    Useful

    Light only what people actually use after dark, and leave the rest of the site dark.

  2. 02

    Targeted

    Aim light down onto the ground with shielded, full cut-off optics, so none goes above the horizontal.

  3. 03

    Low level

    Design to the light level the task needs. Over-lighting adds glare and cost, not safety.

  4. 04

    Controlled

    Dim late at night, or switch with timers and motion sensors, when spaces empty out.

  5. 05

    Warm coloured

    Use 3000 K or warmer, and amber near wildlife, coastlines and nature reserves.

After the Five Principles for Responsible Outdoor Lighting published by DarkSky International and the Illuminating Engineering Society.

Energy savings

Replacing sodium or metal-halide lamps with LED typically cuts energy use by half or more. Put in your own numbers to estimate the saving.
60
150 W
60 W
12 h
₹8 per kWh

Saved every year

₹2,20,752

Energy
27,594 kWh
Reduction
70%
CO₂ avoided
19.6 t
Existing39,420 kWh a year
LED11,826 kWh a year

Estimate only. CO₂ uses the Indian grid average of about 0.71 kg per kWh. Real savings depend on the existing gear, tariffs and burning hours.

Glossary

The terms that come up in specifications, datasheets and tenders.

24 of 24 terms

Anchor bolt cage
The set of foundation bolts, held in position by templates, that is cast into the concrete base and takes the pole's base plate.
BUG rating
A score for a luminaire's backlight, uplight and glare (IES TM-15). Lower numbers mean less stray light.
CCT
Correlated colour temperature, in kelvin. Lower values look warmer (2700 K), higher values cooler (4000 K and above).
CRI (Ra)
Colour rendering index, from 0 to 100. How faithfully colours look under the light compared with daylight. 70 and above suits most outdoor work, 80 and above for plazas and retail.
DALI
Digital Addressable Lighting Interface. A control standard that lets each driver be dimmed, scheduled and monitored individually.
Driver
The electronic gear that powers an LED module, sets its current and allows dimming.
Efficacy
Light output per watt (lm/W). The higher, the less energy for the same light.
Full cut-off
Optics that send no light above the horizontal plane through the lamp. The basis of dark-sky compliant lighting.
Hot-dip galvanising
Dipping fabricated steel in molten zinc so it is coated inside and out, protecting it from corrosion for decades.
IK rating
Resistance of an enclosure to mechanical impact (IEC 62262), from IK00 to IK10 (20 joules).
IP rating
Ingress protection (IEC 60529). The first digit covers solids and dust, the second water.
L70 / L80
The number of operating hours after which an LED still gives 70% or 80% of its original light.
Lumen (lm)
The total amount of light a source gives out.
Lux (lx)
Light falling on a surface: one lumen per square metre. Lighting standards set lux levels for each kind of space.
Maintenance factor
Allowance for dirt and LED ageing when designing light levels, typically 0.5 to 0.8 depending on how clean the site is.
Mounting height
The height of the light source above the ground. It sets how far apart poles can stand.
Outreach
How far an arm carries the luminaire out from the pole, so the light lands over the road rather than the verge.
Photometric file
An IES or LDT file describing how a luminaire spreads light, used in DIALux and similar software for lighting calculations.
Powder coating
A dry polyester paint applied electrostatically and baked on, over a primer, for a tough, even finish in any RAL shade.
RAL
A European colour standard. Quoting a RAL number fixes the exact shade of a finish.
Spigot
The short tube at the top of a pole or end of an arm that a luminaire slides onto and is clamped to.
Surge protection
A device that protects the driver from voltage spikes such as lightning strikes, rated in kilovolts (kV).
Uniformity
How even the light is, as the ratio of minimum to average lux. Higher uniformity avoids dark patches between poles.
Wind load
The force wind exerts on a pole and its luminaires. Shaft size, wall thickness and foundation are designed for the site's wind zone.