Outdoor lighting guide
Heights and spacing
| Space | Product | Mounting height | Spacing | Colour temperature |
|---|---|---|---|---|
| Garden paths and walkways | Bollards | 0.6 – 1.0 m | 4 – 8 m | 2700 – 3000 K |
| Gardens and villa grounds | Garden post tops | 2.5 – 3.5 m | 10 – 15 m | 2700 – 3000 K |
| Heritage streets and plazas | Cast iron and lantern poles | 3 – 5 m | 12 – 20 m | 2700 K |
| Society and internal roads | Round or square poles | 4 – 6 m | 15 – 25 m | 3000 K |
| Avenues and campus roads | Architectural or square poles | 6 – 8 m | 20 – 30 m | 3000 – 4000 K |
| Main roads | Arm-mounted street poles | 9 – 12 m | 30 – 40 m | 4000 K |
| Car parks and yards | Area lighting poles | 8 – 12 m | 25 – 35 m | 4000 K |
| Sports grounds | Area masts | 12 – 15 m | Set by layout | 4000 K |
One side
Road narrower than the mounting height
Staggered
Road up to 1.5 times the mounting height
Opposite
Road wider than 1.5 times the mounting height
Central median
Divided roads, with twin-arm poles in the median
How many poles for a road?
Suggested arrangement
One side
Road narrower than the mounting height
- Spacing
- 28 m
- Poles
- 22
- Luminaires
- 22
A first estimate for budgeting. Final spacing comes from a lighting calculation for the road class, luminaire and optics.
Light distribution
Type I
Narrow, two-way
A long, narrow pool that runs along the path in both directions, with the pole in the middle of the walkway.
Footpaths, cycle tracks, garden walks
Type II
Wide, two-way
Wider than Type I and set to one side, so a pole at the kerb lights the walkway and the edge of the road.
Narrow roads, society lanes, promenades
Type III
Forward throw
Asymmetric light thrown forward across the road from a pole at its edge, with little spill behind.
Roads, avenues, edges of car parks
Type IV
Long forward throw
A semicircle pushed far forward with almost nothing behind the pole. Good where the back of the pole faces a boundary or building.
Perimeters, car parks, building frontages
Type V
Symmetric, all round
An even circle of light all round the pole. The natural choice for post tops, lanterns and 360° bollards in open space.
Plazas, courtyards, junctions, parks
Plan views. Type names follow the IES classification used in photometric files. The dot marks the pole.
Colour temperature
2200 K
Amber
- Near wildlife, wetlands and coastline
- Dark-sky and nature reserves
- Insect-sensitive gardens
2700 K
Warm white
- Heritage streets and conservation areas
- Resorts, temples and hotel drives
- Courtyards and dining terraces
3000 K
Soft white
- Residential streets and societies
- Gardens, parks and campus paths
- Plazas and retail streets
4000 K
Neutral white
- Main roads and highways
- Car parks, yards and logistics
- Sports grounds and security areas
6000 K
Cool daylight
- Highways and expressways
- Industrial yards and logistics hubs
- Security and CCTV-monitored areas
IP and IK ratings
IP65
The usual rating for outdoor luminaires on poles and bollards.
Impact resistance (IK)
Energy of the blow a fitting withstands without damage, tested to IEC 62262.
- IK061 J0.25 kg from 400 mm
- IK072 J0.5 kg from 400 mm
- IK085 J1.7 kg from 300 mm
- IK0910 J5 kg from 200 mm
- IK1020 J5 kg from 400 mm
IK08 is a sensible minimum in public places. Bollards and low columns within reach of crowds are best at IK10.
Luminex ranges rated IK10
Responsible lighting
- 01
Useful
Light only what people actually use after dark, and leave the rest of the site dark.
- 02
Targeted
Aim light down onto the ground with shielded, full cut-off optics, so none goes above the horizontal.
- 03
Low level
Design to the light level the task needs. Over-lighting adds glare and cost, not safety.
- 04
Controlled
Dim late at night, or switch with timers and motion sensors, when spaces empty out.
- 05
Warm coloured
Use 3000 K or warmer, and amber near wildlife, coastlines and nature reserves.
After the Five Principles for Responsible Outdoor Lighting published by DarkSky International and the Illuminating Engineering Society.
Energy savings
Saved every year
₹2,20,752
- Energy
- 27,594 kWh
- Reduction
- 70%
- CO₂ avoided
- 19.6 t
Estimate only. CO₂ uses the Indian grid average of about 0.71 kg per kWh. Real savings depend on the existing gear, tariffs and burning hours.
Glossary
The terms that come up in specifications, datasheets and tenders.
24 of 24 terms
- Anchor bolt cage
- The set of foundation bolts, held in position by templates, that is cast into the concrete base and takes the pole's base plate.
- BUG rating
- A score for a luminaire's backlight, uplight and glare (IES TM-15). Lower numbers mean less stray light.
- CCT
- Correlated colour temperature, in kelvin. Lower values look warmer (2700 K), higher values cooler (4000 K and above).
- CRI (Ra)
- Colour rendering index, from 0 to 100. How faithfully colours look under the light compared with daylight. 70 and above suits most outdoor work, 80 and above for plazas and retail.
- DALI
- Digital Addressable Lighting Interface. A control standard that lets each driver be dimmed, scheduled and monitored individually.
- Driver
- The electronic gear that powers an LED module, sets its current and allows dimming.
- Efficacy
- Light output per watt (lm/W). The higher, the less energy for the same light.
- Full cut-off
- Optics that send no light above the horizontal plane through the lamp. The basis of dark-sky compliant lighting.
- Hot-dip galvanising
- Dipping fabricated steel in molten zinc so it is coated inside and out, protecting it from corrosion for decades.
- IK rating
- Resistance of an enclosure to mechanical impact (IEC 62262), from IK00 to IK10 (20 joules).
- IP rating
- Ingress protection (IEC 60529). The first digit covers solids and dust, the second water.
- L70 / L80
- The number of operating hours after which an LED still gives 70% or 80% of its original light.
- Lumen (lm)
- The total amount of light a source gives out.
- Lux (lx)
- Light falling on a surface: one lumen per square metre. Lighting standards set lux levels for each kind of space.
- Maintenance factor
- Allowance for dirt and LED ageing when designing light levels, typically 0.5 to 0.8 depending on how clean the site is.
- Mounting height
- The height of the light source above the ground. It sets how far apart poles can stand.
- Outreach
- How far an arm carries the luminaire out from the pole, so the light lands over the road rather than the verge.
- Photometric file
- An IES or LDT file describing how a luminaire spreads light, used in DIALux and similar software for lighting calculations.
- Powder coating
- A dry polyester paint applied electrostatically and baked on, over a primer, for a tough, even finish in any RAL shade.
- RAL
- A European colour standard. Quoting a RAL number fixes the exact shade of a finish.
- Spigot
- The short tube at the top of a pole or end of an arm that a luminaire slides onto and is clamped to.
- Surge protection
- A device that protects the driver from voltage spikes such as lightning strikes, rated in kilovolts (kV).
- Uniformity
- How even the light is, as the ratio of minimum to average lux. Higher uniformity avoids dark patches between poles.
- Wind load
- The force wind exerts on a pole and its luminaires. Shaft size, wall thickness and foundation are designed for the site's wind zone.